You are here:
UV and Visible spectrophotometer, reference beam, 4 nm bandwidth, 1 nm accuracy, with methods for analyzing water quality, including COD. It allows the creation of customized curves with formulas and the use of 5 measurement modes, including kinetics, with accessories available as an option.

Reference Beam UV Spectrophotometer – UVILINE 9600

Ref: 70VI0511A
Wavelenghts range: 190 – 1100 nm

Spectrophotometer endowed with 86 pre-recorded methods including COD, nitrogen, nitrates, etc. in the visible range. UV extension allows precise estimation of essential parameters such as organic matter at 254 nm, thus expanding your analysis capabilities.

The UVILINE stands out with high resolution and exceptional precision due to the reference beam, ideal for water quality analysis using its pre-recorded methods and accessories.

Aqualabo’s Uviline spectrophotometers offer the flexibility to create custom calibration curves across the entire UV and/or visible electromagnetic spectrum.

Internal storage of 100 methods, 30 graphs, and 1000 results (approx. 5000 individual values, 500 spectra and 400 kinetic curves). Data can also be stored on a USB stick depending on its capacity or on a computer using the free SPECTRALAB software.

Uviline measurement methods :
– Absorbance/Transmittance: Absorbance or transmittance can be measured relative to air or to a reference solution defined by the user
– Concentration: Up to 10 standards. The calibration curve equation or the factor value can be entered, as well as Absorbance/Concentration value pairs.
– Multi-Wavelength: Reading of up to 10 wavelengths with related formula. Ability to integrate additional variables (volume, pH, temperature) and to check if a value meets a condition.
– Spectrum Scanning: Display of dynamic graphs, zoom, point marking, peak and trough detection, curve comparison, determining the peak area, derivation, and other evaluation functions.
– Kinetics: Easy programming with curve management, zoom, min./max. definition, slope calculation, kinetic comparison, and other assessment features.

Accessories for the Uviline Quick-lock System :
– 10 mm tank holder thermostatically controlled by Peltier effect
– 5/10/20/50/100 mm universal tank holder and 16 mm tube
– 5+1 tank changer to perform sequential analyzes
– Sipper (sample suction system) to minimize sample handling.

• Optimal precision thanks to the reference beam.
• 4 nm bandwidth resolution
• 86 pre-recorded methods including COD, nitrogen, nitrates, etc.
• Multi-tank accessories, sample suction system and other Quick-Lock accessories
• Special mode: Calculation based on the customizable mathematical formula, integration of additional variables and measurement conditions.

• Instruments available on 4 continents
• Manufactured and serviced in France
• Free PC software for full control of the instrument and its accessories.
• Lamp lifespan: Up to 4 years on Uviline 9300 and no lamp to change on Uviline 9600

Similar products

Why trust AQUALABO?

AQUALABO, a French company, offers a combination of experience, innovation, international presence, adaptability, and ecological commitment, making it a trusted partner for water quality control.

FAQ Reference Beam UV Spectrophotometer – UVILINE 9600

SPECTRALAB is a free downloadable multilingual software, offering 5 measurement modes Absorbance/Transmittance, Concentration, Multi Wavelength, Spectrum Scanning and Kinetics. It offers a user-friendly and intuitive interface, allowing full control of the instrument and its accessories.

PRIM spectrophotometers can store up to 50 methods. Data can also be stored on a computer using the free SPECTRALAB software.
Uviline spectrophotometers offer internal storage of 100 methods, 30 graphs, and 1000 results (approx. 5000 individual values, 500 spectra and 400 kinetic curves). Data can also be stored on a USB stick depending on its capacity or on a computer using the free SPECTRALAB software.

- Absorbance/Transmittance: Absorbance or transmittance can be measured relative to air or to a reference solution defined by the user
- Concentration: Up to 10 standards. The calibration curve equation or the factor value can be entered, as well as Absorbance/Concentration value pairs.
- Multi-Wavelength: Reading of up to 10 wavelengths with related formula. Ability to integrate additional variables (volume, pH, temperature) and to check if a value meets a condition.
- Spectrum Scanning: Display of dynamic graphs, zoom, point marking, peak and trough detection, curve comparison, determining the peak area, derivation, and other evaluation functions.
- Kinetics: Easy programming with curve management, zoom, min./max. definition, slope calculation, kinetic comparison, and other assessment features.

- 10 mm tank holder thermostatically controlled by Peltier effect
- 5/10/20/50/100 mm universal tank holder and 16 mm tube
- 5+1 tank changer to perform sequential analyzes
- Sipper (sample suction system) to minimize sample handling.